Related Experiment Video
Updated: Mar 20, 2026

Measurement of Factor V Activity in Human Plasma Using a Microplate Coagulation Assay
Published on: September 9, 2012
Isolated Acquired FX Deficiency: A Case Report
A female with no previous history of bleeding presented with active bleeding from multiple body sites, declining hemoglolobin levels, and markedly prolonged prothrombin times (PT), and activated partial thromboplastin times (APTT) with incomplete correction on PT mix assays. This patient showed a severe deficiency of factor X. FX levels and bleeding were refractory to multiple transfusions of fresh frozen plasma. Although plasmapheresis was started with concomitant intravenous immunoglobulin and steroid therapy, the patient died.
A female with no previous history of bleeding presented with active bleeding from multiple body sites, declining hemoglolobin levels, and markedly prolonged prothrombin times (PT), and activated partial thromboplastin times (APTT) with incomplete correction on PT mix assays. This patient showed a severe deficiency of factor X. FX levels and bleeding were refractory to multiple transfusions of fresh frozen plasma. Although plasmapheresis was started with concomitant intravenous immunoglobulin and steroid therapy, the patient died.
More Related Videos
Related Concept Videos
Disorders of Hemostasis
Thromboembolic Disorders
Two factors primarily cause thromboembolic conditions.
Clot Retraction and Fibrinolysis