Related Experiment Video
Updated: Mar 19, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
End-inspiratory molar mass step correction for analysis of infant multiple breath washout tests
Rachel E Foong1,2, Tim Rosenow1,2, Shannon J Simpson1,2
1Telethon Kids Institute, Subiaco, Western Australia, Australia.
Abstract:
A refined software algorithm was recently proposed for the analysis of infant multiple breath washout (MBW) measurements. The proposed algorithm uses the change in end-inspiratory molar mass between the wash-in and wash-out curves (EIMM-step) to define the required step response correction of the MM signal and is assumed to provide an accurate evaluation of complete washout of the tracer gas, in comparison to the current software algorithm which applies the change in end-expiratory molar mass (EEMM)-step. We aimed to evaluate the use of the EIMM-step method in a broad range of infants. We performed retrospective analyses comparing the EIMM- and EEMM-step change methods in MBW data collected from infants with cystic fibrosis (CF), infants born preterm, and healthy infants using an ultrasonic flowmeter. We found that the EIMM-step correction significantly increased LCI and functional residual capacity (FRC) in infants with CF, preterm infants, and healthy infants compared with the EEMM-step method. In addition, more than half the measurements that were technically acceptable and repeatable using the EEMM-step correction in healthy infants were excluded after using the EIMM-step correction. We found a large difference between the EIMM- and EEMM-steps in healthy infants indicating incomplete washout, suggesting the need for a longer washout time with using the EIMM-step analysis method. The data indicates that the EIMM-step analysis method may have the potential to generate false abnormal LCI values in individuals without lung disease. Revised normative data may be required if this method is universally adopted. Pediatr Pulmonol. 2017;52:10-13. © 2016 Wiley Periodicals, Inc.
More Related Videos
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Respiratory Volumes and Capacities
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Application of Integration: Problem Solving
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Lung Capacity