Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch

Yi-Chun Du1, Bee-Yen Lim2, Wei-Siang Ciou3

  • 1Department of Electrical Engineering, Southern Taiwan University of Science and Technology, Tainan 71005, Taiwan. terrydu@stust.edu.tw.

Summary

This study introduces a wearable array sensing patch for detecting blood leakage during hemodialysis (HD). The device enhances patient safety by providing early warnings of potential dangers.

Related Concept Videos

Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
2.9K
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
1.6K
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.9K
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.8K
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
2.1K