Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
A procedure for comprehensive two-dimensional gas chromatography retention time locked dual detection
John Mommers1, Erik Ritzen2, Thomas Dutriez3
1DSM Resolve, P.O. Box 18, 6160 MD Geleen, The Netherlands; Analytical Chemistry and Forensic Analyses Group, Van 't Hoff Institute for Molecular Sciences, University of Amsterdam, Amsterdam, The Netherlands.
Abstract:
In this paper, a novel, and easy to perform, retention time locking procedure for locking primary and secondary retention times of detector signals in comprehensive two-dimensional gas chromatography (GCxGC) dual-detection is proposed and its advantages are demonstrated and discussed. The dual detection retention time locking procedure is a 2-step process for a GCxGC system in which the effluent of the primary column is split, by using a pressure regulated splitter, towards the GCxGC modulator using two identical secondary GC columns of which one is installed in the main GC oven and the other is installed in a secondary GC oven. The first step of the locking procedure is to minimize the secondary retention time difference between both detectors of a compound, which has a retention factor (k) close to 0. This is done by stepwise altering the effective secondary column length, simply by sliding the secondary column, which is installed in the main oven, forwards or backwards through the modulator. The second step is to minimize the secondary retention time difference of a compound which has a significant retention in both dimensions. This is done by stepwise altering the secondary oven temperature rate. This locking procedure was successfully demonstrated for the analysis of a diesel sample by GCxGC coupled to a time of flight mass spectrometer (TOFMS) and a nitrogen chemiluminescence detector (NCD) and by GCxGC coupled to a TOFMS and a flame ionization detector (FID). For all compounds the average absolute secondary retention time differences between the NCD or the FID and the TOFMS detectors were 0.03, and 0.07s, respectively, which are significantly less than the average peak widths at half heights, which was 0.2s.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...