Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

9.3K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.3K
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

493
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
493
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

572
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
572
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

1.1K
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
1.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A survey of image-guided radiation therapy practices around the globe.

Annals of the ICRP·2026
Same author

The case for individualisation of radiological protection in medicine.

Annals of the ICRP·2026
Same author

A clinically feasible model for size-specific estimation of eye lens dose in head CT.

Radiological physics and technology·2026
Same author

The determination of coefficients for size specific effective dose for adult and pediatric patients undergoing routine computed tomography examinations.

Journal of radiological protection : official journal of the Society for Radiological Protection·2024
Same author

Variations in size-specific effective dose with patient stature and beam width for kV cone beam CT imaging in radiotherapy.

Journal of radiological protection : official journal of the Society for Radiological Protection·2022
Same author

An international survey of imaging practices in radiotherapy.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2021
Same journal

Re-evaluating physical shielding in paediatric chest computed tomography: a phantom-based assessment of dose distribution and image quality.

Journal of radiological protection : official journal of the Society for Radiological Protection·2026
Same journal

Occupational Radiation Exposure in Spine Surgery: Organ-specific OSL Phantom Dosimetry and Workload-based Risk Assessment.

Journal of radiological protection : official journal of the Society for Radiological Protection·2026
Same journal

A dosemeter for the public based on NaCl pellets for use in radiological or nuclear emergencies.

Journal of radiological protection : official journal of the Society for Radiological Protection·2026
Same journal

Dose Simulation for the MATROSHKA-R Experiment onboard the International Space Station Using a High-Fidelity Model of the Zvezda Module.

Journal of radiological protection : official journal of the Society for Radiological Protection·2026
Same journal

Reflecting Local Economic Parameters in ALARA Evaluations for the Reuse of Decommissioning Remaining Building.

Journal of radiological protection : official journal of the Society for Radiological Protection·2026
Same journal

OBITUARYRoger Clarke 1943-2026.

Journal of radiological protection : official journal of the Society for Radiological Protection·2026
See all related articles

Related Experiment Video

Updated: Mar 16, 2026

Surgery and Sample Processing for Correlative Imaging of the Murine Pulmonary Valve
07:34

Surgery and Sample Processing for Correlative Imaging of the Murine Pulmonary Valve

Published on: August 5, 2021

3.0K

Setting up computed tomography automatic tube current modulation systems.

C J Martin1, S Sookpeng

  • 1Health Physics, Department of Clinical Physics, University of Glasgow, Gartnavel Royal Hospital, Glasgow, G12 0XH, UK.

Journal of Radiological Protection : Official Journal of the Society for Radiological Protection
|August 4, 2016
PubMed
Summary
This summary is machine-generated.

Automatic tube current modulation (ATCM) reduces patient radiation doses in CT scans by adjusting x-ray beam intensity. This paper reviews ATCM systems and proposes a framework for testing and optimizing protocols to ensure consistent image quality and patient safety.

More Related Videos

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
10:21

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function

Published on: August 8, 2019

8.9K
Using Tomoauto: A Protocol for High-throughput Automated Cryo-electron Tomography
11:33

Using Tomoauto: A Protocol for High-throughput Automated Cryo-electron Tomography

Published on: January 30, 2016

11.5K

Related Experiment Videos

Last Updated: Mar 16, 2026

Surgery and Sample Processing for Correlative Imaging of the Murine Pulmonary Valve
07:34

Surgery and Sample Processing for Correlative Imaging of the Murine Pulmonary Valve

Published on: August 5, 2021

3.0K
Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
10:21

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function

Published on: August 8, 2019

8.9K
Using Tomoauto: A Protocol for High-throughput Automated Cryo-electron Tomography
11:33

Using Tomoauto: A Protocol for High-throughput Automated Cryo-electron Tomography

Published on: January 30, 2016

11.5K

Area of Science:

  • Medical Physics
  • Radiological Imaging
  • Radiation Dosimetry

Background:

  • Automatic tube current modulation (ATCM) is crucial for reducing patient radiation doses in computed tomography (CT) scans.
  • ATCM systems utilize scan projection radiographs (SPRs) to assess x-ray beam attenuation and maintain image quality.
  • Current methods for assessing image quality and testing ATCM systems lack standardization, posing challenges for consistent application.

Purpose of the Study:

  • To review the operational principles of various ATCM systems.
  • To explore and evaluate different methods for testing ATCM performance.
  • To establish a framework for optimizing clinical protocols and ensuring reliable dose reduction and image quality.

Main Methods:

  • Review of ATCM system operations and image quality metrics used by manufacturers.
  • Consideration of phantom-based testing using anatomical and geometrical phantoms.
  • Analysis of factors influencing ATCM, including SPRs, image thickness, and noise/reference image selection.

Main Results:

  • Different CT scanner manufacturers employ varied metrics for assessing image quality and ATCM performance.
  • Phantom testing with anatomical or geometrical phantoms can characterize ATCM modulation.
  • Selection of image quality reference or noise reference significantly impacts protocol optimization and dose management.

Conclusions:

  • A standardized testing framework is needed for ATCM systems to ensure consistent dose reduction and image quality.
  • Understanding ATCM system operation and protocol parameters is essential for users.
  • Commissioning CT scanners with suitable phantoms is vital for establishing ATCM system behavior and ensuring patient safety.