Related Experiment Video
Updated: Mar 13, 2026

Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging
Published on: February 3, 2015
90Y Digital PET/CT Imaging Following Radioembolization
Chadwick L Wright1, Jun Zhang, Katherine Binzel
1From the *Wright Center of Innovation and Biomedical Imaging, Department of Radiology, and †Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Columbus, OH.
New digital photon counting PET/CT offers superior imaging for Yttrium-90 radioembolization (RE) liver metastases. This advanced technology provides better contrast and biodistribution visualization compared to older methods.
Area of Science:
- Nuclear Medicine
- Radiology
- Oncology
Background:
- Yttrium-90 (Y) radioembolization (RE) is used for liver metastases.
- Conventional photomultiplier detector PET has limitations in imaging Y-90 RE.
- Bremsstrahlung SPECT/CT is an alternative imaging modality.
Observation:
- A 54-year-old man with rectal carcinoma liver metastases underwent Y-90 RE.
- The patient was subsequently imaged using novel solid-state digital photon counting PET/CT (Vereos 64 TOF PET/CT).
- Imaging was performed 26 hours post-RE.
Findings:
- Digital PET/CT demonstrated improved image quality compared to Bremsstrahlung SPECT/CT.
- Enhanced Y-90 to background contrast was observed with digital PET/CT.
- Accurate visualization of Y-90 biodistribution was achieved with the new technology.
Implications:
- Solid-state digital photon counting PET/CT enhances post-Y-90 RE imaging assessment.
- This technology may improve treatment monitoring and patient outcomes.
- Digital PET/CT offers a valuable advancement for Y-90 RE therapy evaluation.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...