Related Experiment Video
Updated: Mar 12, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Dose volume uniformity index: a simple tool for treatment plan evaluation in brachytherapy
1Department of Radiation Oncology, Institute Rotary Cancer Hospital, All India Institute of Medical Sciences, New Delhi - 110 029, India.
Purpose:
In radiotherapy treatment planning, dose homogeneity inside the target volume plays a significant role in the final treatment outcome. Especially in brachytherapy where there is a steep dose gradient in the dose distribution inside the target volume, comparing the plans based on the dose homogeneity helps in assessing the high dose volume inside the final treatment plan. In brachytherapy, the dose inhomogeneity inside the target volume depends on many factors such as the type of sources, placement of these radioactive sources, distance between the applicators/implant tubes, dwell time of the source, etc. In this study, a simple index, the dose volume uniformity index (DVUI), has been proposed to study the dose homogeneity inside the target volume. This index gives the total dose volume inhomogeneity inside a given prescription isoline.
Material And Methods:
To demonstrate the proposed DVUI in this study, a single plane implant (breast: 6 catheters), a double plane implant (breast: 9 catheters) and a tongue implant (5 catheters) were selected. The catheters were reconstructed from the CT image datasets in the Plato treatment planning system. The doses for the single, double and tongue implants were prescribed to the reference dose rate as per the Paris technique. DVUI was computed from the cumulative dose volume histogram.
Results:
For a volume receiving a uniform dose inside the prescription isoline, the DVUI is 1. Any value of DVUI > 1 shows the presence of a relatively high dose volume inside the prescription isoline. In addition to the concept of DVUI, a simple conformality index, the dose volume conformality index (DVCI), has also been proposed in this study based on the DVUI.
Conclusion:
The DVUI and the proposed DVCI in this study provide an easy way of comparing the rival plans in brachytherapy.
Related Concept Videos
Dose Size and Dosing Frequency: Determination Methods
Dosage Regimen: Individualization
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Dose Response Curve: Conventional Versus Nonmonotonic