Related Experiment Video
Updated: Mar 11, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Work of Breathing in Fixed and Pressure Relief Continuous Positive Airway Pressure (C-Flex™): A post hoc Analysis
Lukas Jerrentrup1, Sebastian Canisius, Susanne Wilhelm
1Department of Medicine, Pulmonary and Critical Care Medicine, University Medical Center Giessen and Marburg, Philipps-Universität Marburg, Marburg, Germany.
Background:
Expiratory pressure relief continuous positive airway pressure (pressure relief CPAP; C-Flex™) causes increases in inspiratory duty cycle and shortening of expiratory time. It has been suggested that these changes are caused by an increase in work of breathing.
Objectives:
We studied the effects of C-Flex on work of breathing and intrinsic positive end-expiratory pressure as compared to fixed CPAP.
Methods:
Work of breathing was analyzed in 24 patients with obstructive sleep apnea during treatment with fixed CPAP and C-Flex with 3 different pressure relief settings in a randomized order during rapid-eye-movement (REM) and non-REM sleep. Work of breathing was assessed on a breath-by-breath basis using a piezoelectric esophageal pressure catheter and a pneumotachograph for measuring airflow.
Results:
We found there was no increase in inspiratory work of breathing observed using C-Flex compared to fixed CPAP. Instead, we found a linear decrease in inspiratory work of breathing with increasing pressure relief, with a mean difference of 1.22 J/min between CPAP and maximum pressure release (C-Flex 3; 90% of the value with nasal CPAP); however, the decrease was not statistically significant. The decrease in inspiratory work of breathing associated with C-Flex has a significant inverse correlation with BMI.
Conclusions:
The C-Flex technology does not change work of breathing but shows a tendency towards a reduction of inspiratory work of breathing in patients with a lower BMI using higher C-Flex. The effect is probably caused by diminishing airway resistance generated by the positive end-expiratory pressure. Our findings may lead to additional fields of application of the C-Flex technology, such as chronic obstructive pulmonary disease or muscular dystrophy.
More Related Videos
09:31Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation I: Indication and Settings
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...