Related Experiment Video
Updated: Mar 10, 2026

Retinal Pigment Epithelium Transplantation in a Non-human Primate Model for Degenerative Retinal Diseases
Published on: June 14, 2021
GORE-TEX VASCULAR GRAFT FOR MACULAR BUCKLING IN HIGH MYOPIA EYES
Pei-Chang Wu1, Jiunn-Jye Sheu, Yi-Hao Chen
1*Department of Ophthalmology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China; and †Division of Thoracic and Cardiovascular Surgery, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan, Republic of China.
Purpose:
To evaluate a new application of an expanded polytetrafluoroethylene (Gore-Tex) vascular graft for use in macular buckling surgery for treatment of highly myopic eyes.
Methods:
The Gore-Tex vascular graft was used as a macular buckling material in eight consecutive cases of myopic macular diseases which included fovea detachment, foveoschisis, or macular hole retinal detachment.
Results:
Retinal reattachment was achieved in all cases except one which had partial resolution (88%). The postoperative best-corrected visual acuity ranged from 20/2000 to 20/100 depending on the degree preexisting macular degeneration, and significant better than the preoperative best-corrected visual acuity (P = 0.048, paired t-test). During the follow-up period, which ranged from 8 months to 3 years, no eye developed buckle-related complications such as infection or dislocation.
Conclusion:
The initial pilot results from this series using a Gore-Tex graft for macular buckling is promising. Throughout the follow-up period, the Gore-Tex was well tolerated in the highly myopic eyes. Large scale and long-term follow-up is warranted.