Related Experiment Video
Updated: Mar 9, 2026

Method for Recording Broadband High Resolution Emission Spectra of Laboratory Lightning Arcs
Published on: August 27, 2019
Absolute Spatially- and Temporally-Resolved Optical Emission Measurements of rf Glow Discharges in Argon
S Djurović1, J R Roberts1, M A Sobolewski1
1National Institute of Standards and Technology, Gaithersburg, MD 20899-0001.
Abstract:
Spatially- and temporally-resolved measurements of optical emission intensities are presented from rf discharges in argon over a wide range of pressures (6.7 to 133 Pa) and applied rf voltages (75 to 200 V). Results of measurements of emission intensities are presented for both an atomic transition (Ar I, 750.4 nm) and an ionic transition (Ar II, 434.8 nm). The absolute scale of these optical emissions has been determined by comparison with the optical emission from a calibrated standard lamp. All measurements were made in a well-defined rf reactor. They provide detailed characterization of local time-resolved plasma conditions suitable for the comparison with results from other experiments and theoretical models. These measurements represent a new level of detail in diagnostic measurements of rf plasmas, and provide insight into the electron transport properties of rf discharges.
More Related Videos
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Instrumentation
Atomic Fluorescence Spectroscopy
Atomic Emission Spectroscopy: Lab
Flame Photometry: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...