V-band gapless OFDM RoF system with power detector down-conversion and novel Volterra nonlinear filtering

Optics Letters
|January 13, 2017
PubMed

Related Concept Videos

Downsampling01:20

Downsampling

When considering a sampled sequence with zero values between sampling instants, one can replace it by taking every N-th value of the sequence. At these integer multiples of N, the original and sampled sequences coincide. This process, known as decimation, involves extracting every N-th sample from a sequence, thereby creating a more efficient sequence.
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
742
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
627
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
403
Frequency Response of Op Amp Circuits01:20

Frequency Response of Op Amp Circuits

Operational amplifiers (op-amp) are used in signal conditioning, filtering, or for performing mathematical operations such as addition, subtraction, integration, and differentiation. The frequency response of an op-amp is an important aspect that describes how the gain of the amplifier varies with frequency.
Frequency Response and Gain:
The gain of the op-amp, A(ω), is not a constant but a function of the input signal frequency. An op-amp can maintain a constant gain at low frequencies, known...
827
Upsampling01:22

Upsampling

Managing signal sampling rates is essential in digital signal processing to maintain signal integrity. A decimated signal, characterized by a reduced frequency range due to its lower sampling rate, can be upsampled by inserting zeros between each sample. This upsampling process expands the original spectrum and introduces repeated spectral replicas at intervals dictated by the new Nyquist frequency. To refine this zero-inserted sequence, it is passed through a lowpass filter with a cutoff...
676
Discrete-time Fourier transform01:26

Discrete-time Fourier transform

The Discrete-Time Fourier Transform (DTFT) is an essential mathematical tool for analyzing discrete-time signals, converting them from the time domain to the frequency domain. This transformation allows for examining the frequency components of discrete signals, providing insights into their spectral characteristics. In the DTFT, the continuous integral used in the continuous-time Fourier transform is replaced by a summation to accommodate the discrete nature of the signal.
One of the notable...
1.2K