Published on: January 26, 2019
Noncontact Vision-Based Cardiopulmonary Monitoring in Different Sleeping Positions
Abstract:
Individuals with obstructive sleep apnea (OSA) can experience partial or complete collapse of the upper airway during sleep. This condition affects between 10-17% of adult men and 3-9% of adult women, requiring arousal to resume regular breathing. Frequent arousals disrupt proper sleeping patterns and cause daytime sleepiness. Untreated OSA has been linked to serious medical issues including cardiovascular disease and diabetes. Unfortunately, diagnosis rates are low (∼20%) and current sleep monitoring options are expensive, time consuming, and uncomfortable. Toward the development of a convenient, noncontact OSA monitoring system, this paper presents a simple, computer vision-based method to monitor cardiopulmonary signals (respiratory and heart rates) during sleep. System testing was performed with 17 healthy participants in five different simulated sleep positions. To monitor cardiopulmonary rates, distinctive points are automatically detected and tracked in infrared image sequences. Blind source separation is applied to extract candidate signals of interest. The optimal respiratory and heart rates are determined using periodicity measures based on spectral analysis. Estimates were validated by comparison to polysomnography recordings. The system achieved a mean percentage error of 3.4% and 5.0% for respiratory rate and heart rate, respectively. This study represents an important step in building an accessible, unobtrusive solution for sleep apnea diagnosis.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:12Real-Time Monitoring of Neurocritical Patients with Diffuse Optical Spectroscopies
Published on: November 19, 2020
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Holter Monitor: 24-Hour Monitoring
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Sleep Apnea
The condition is more prevalent among...