Related Experiment Video
Updated: Mar 8, 2026

Blue-hazard-free Candlelight OLED
Published on: March 19, 2017
Monitor brightness changes under a wide range of surround conditions
Abstract:
Display brightness data were collected under a wide range of surround conditions. A 24 in. (60.96 cm) LCD display was used to generate color stimuli, and a 107 in. (271.78 cm) two-dimensional illuminator was used to generate various surround conditions. The brightness values of the display under 89 monitor-surround-luminance combinations were collected from 10 or 24 observers. The surround ratio, SR, i.e., the luminance ratio between the surround and the monitor, varied from 0 to 90. Based on the collected brightness data, we propose a new c value as the log function of the surround ratio, SR, to improve the performance of the CIECAM02 brightness predictor Q.
Related Concept Videos
Photoreceptors and Visual Pathways
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Variables Affecting Phosphorescence and Fluorescence
Light Acquisition
Biasing of P-N Junction
In equilibrium, no external voltage is applied across the p-n junction. The depletion region is formed at the junction interface due to the diffusion of carriers, which leaves behind charged dopants, acceptors on the p-side, and donors on the n-side. These immobile charges create an electric field that prevents further diffusion of carriers. The related energy band...
Color Vision