Heart rate monitoring from wrist-type PPG based on singular spectrum analysis with motion decision
Abstract:
Heart rate (HR) monitoring is necessary for daily healthcare. Wrist-type photoplethsmography (PPG) is a convenient and non-invasive technique for HR monitoring. However, motion artifacts (MA) caused by subjects' movements can extremely interfere the results of HR monitoring. In this paper, we propose a high accuracy method using motion decision, singular spectrum analysis (SSA) and spectral peak searching for daily HR estimation. The proposed approach was evaluated on 8 subjects under a series of different motion states. Compared with electrocardiogram (ECG) recorded simultaneously, the experimental results indicated that the averaged absolute estimation error was 2.33 beats per minute (BPM).