Related Experiment Video
Updated: Mar 6, 2026

High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
Published on: September 22, 2017
Relative biological effectiveness in a proton spread-out Bragg peak formed by pencil beam scanning mode
Anna Michaelidesová1,2,3, Jana Vachelová4, Monika Puchalska5
1Nuclear Physics Institute of the Czech Academy of Sciences, Řež 130, 25068, Řež, Czech Republic. anna.michaelidesova@odz.ujf.cas.cz.
Abstract:
In recent years, there is an increased interest in using scanning modes in proton therapy, due to the more conformal dose distributions, thanks to the spot-weighted dose delivery. The dose rate in each spot is however much higher than the dose rate when using passive irradiation modes, which could affect the cell response. The purpose of this work was to investigate how the relative biological effectiveness changes along the spread-out Bragg peak created by protons delivered by the pencil beam scanning mode. Cell survival and micronuclei formation were investigated in four positions along the spread-out Bragg peak for various doses. Monte Carlo simulations were used to estimate the dose-averaged linear energy transfer values in the irradiation positions. The cell survival was found to decrease the deeper the sample was placed in the spread-out Bragg peak, which corresponds to the higher linear energy transfer values found using Monte Carlo simulations. The micronuclei frequencies indicate more complex cell injuries at that distal position compared to the proximal part of the spread-out Bragg peak. The relative biological effectiveness determined in this study varies significantly and systematically from 1.1, which is recommended value by the International Commission on Radiation Units, in all the studied positions. In the distal position of spread-out Bragg peak the relative biological effectiveness values were found to be 2.05 ± 0.44, 1.85 ± 0.42, 1.53 ± 0.38 for survival levels 90, 50 and 10%, respectively.
More Related Videos
10:39Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
Related Concept Videos
Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
Scanning Electron Microscopy
Fundamental Principles
Accelerated...