Related Experiment Video
Updated: Mar 5, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Extraction of a well fixed but fractured ceramic acetabular liner
David Ferguson1, Robert Metcalf1
1Huddersfield Royal Infirmary, Lindley, UK.
Abstract:
Ceramic fractures have been reported to occur in hip replacements, but the techniques used to extract a well fixed but fractured component are not commonly described. We present a case of ceramic liner fracture and validate a modification of a previously reported extraction technique that allowed us to save the acetabular cup and insert a polyethylene liner. With an increasing trend in ceramic bearing usage, it is likely that the number of ceramic liner fractures will increase and therefore knowledge of successful extraction techniques will be desirable.