Objectives:
To examine (1) the intra-rater, interrater, and test-retest reliabilities of the timed Up and Go test with a motor task (TUGmotor) in terms of the number of steps taken in the test and completion time in a population with chronic stroke; (2) the relation between stroke-specific impairments and the number of steps taken in the test and the completion time; (3) the minimum detectable change in TUGmotor times; and (4) the cutoff time that best discriminates the performance of people with stroke from that of older adults without stroke.
Design:
Cross-sectional study.
Setting:
University-based rehabilitation center.
Participants:
A sample (N=65) of chronic stroke survivors (n=33) and healthy older adults (n=32).
Interventions:
Not applicable.
Main Outcome Measures:
TUGmotor times and number of steps taken; Fugl-Meyer Assessment for the Lower Extremities score; handheld dynamometer measurements of hip abductor, knee flexor and extensor, and ankle dorsiflexor and plantar flexor muscle strength; 5-times sit-to-stand test time, Berg Balance Scale score; conventional timed Up and Go test time, and Activities-specific Balance Confidence scale and Community Integration Measure questionnaire scores.
Results:
The TUGmotor completion times and number of steps demonstrated excellent intra-rater, interrater, and test-retest reliabilities. The TUGmotor times correlated significantly with the Fugl-Meyer Assessment for the Lower Extremities and Berg Balance Scale scores, with hip abductor, knee flexor, ankle dorsiflexor and plantar flexor strength on the paretic side, with 5-times sit-to-stand test times, and with times on the conventional timed Up and Go test. The minimum detectable change in TUGmotor time was 3.53 seconds in stroke survivors. A TUGmotor cutoff time of 13.49 seconds was found to best discriminate the performance of stroke survivors from that of older adults without stroke.
Conclusions:
The TUGmotor is a reliable, valid, and easy-to-administer clinical tool for assessing advanced functional mobility after a stroke.