Related Experiment Video
Updated: Mar 3, 2026

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
Clinical Implications of Physiologic Flow Adjustment in Continuous-Flow Left Ventricular Assist Devices
Vakhtang Tchantchaleishvili1, Jessica G Y Luc, Caitlin M Cohan
1From the *Department of Cardiovascular Surgery, Mayo Clinic, Rochester, Minnesota; †Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada; ‡Department of Surgery, Alameda Health System, Oakland, California; §Faculty of Medicine, University of Sydney, Sydney, Australia; ¶Department of Medicine and Health Sciences, Linkoping University, Linkoping, Sweden; ‖1Department of Mechanical Engineering, Rochester Institute of Technology, Rochester, New York; and #Department of Thoracic and Cardiovascular Surgery, University of Louisville, Louisville, Kentucky.
Abstract:
There is increasing evidence for successful management of end-stage heart failure with continuous-flow left ventricular assist device (CF-LVAD) technology. However, passive flow adjustment at fixed CF-LVAD speed is susceptible to flow balancing issues as well as adverse hemodynamic effects relating to the diminished arterial pulse pressure and flow. With current therapy, flow cannot be adjusted with changes in venous return, which can vary significantly with volume status. This limits the performance and safety of CF-LVAD. Active flow adjustment strategies have been proposed to improve the synchrony between the pump and the native cardiovascular system, mimicking the Frank-Starling mechanism of the heart. These flow adjustment strategies include modulation by CF-LVAD pump speed by synchrony and maintenance of constant flow or constant pressure head, or a combination of these variables. However, none of these adjustment strategies have evolved sufficiently to gain widespread attention. Herein we review the current challenges and future directions of CF-LVAD therapy and sensor technology focusing on the development of a physiologic, long-term active flow adjustment strategy for CF-LVADs.
More Related Videos
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
05:18Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
Related Concept Videos
Heart Failure VI: Adjunct Therapies
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Heart Failure V: Medical Management