CKD-EPI equation: A suitable Glomerular Filtration Rate estimate for drug dosing in HIV-infected patients
A Gagneux-Brunon1, E Botelho-Nevers1, P Delanaye2
1Department of infectious and tropical diseases, university hospital of Saint-Étienne, PRES de Lyon, Lyon, France; Groupe immunité muqueuse et agents pathogènes, université Jean-Monnet, université de Lyon, 42270 Saint-Priest-en-Jarez, France.
Objectives:
To evaluate concordance between glomerular filtration rate (GFR) estimates (Cockcroft and Gault, modification of diet in renal diseases, chronic kidney disease epidemiology study group equations) for drug dosing in HIV-infected patients.
Patients And Methods:
We performed a monocentric study. GFR was measured using the gold standard method (plasma clearance of iohexol) in 230 HIV-infected patients. Concordance rate was evaluated between measured GFR (mGFR) and estimated GFR (eGFR) for different GFR categories (GFR>90 mL/min, GFR<90 mL/min, GFR>70 mL/min, and GFR<70 mL/min). MDRD and CKD-EPI were used with and without indexation to body surface area (BSA).
Results:
Mean age was 48±10 years, mean mGFR was 101±26 mL/min. Concordance between mGFR and eGFR estimated with CG, CKD-EPI (indexed and not indexed to BSA), or MDRD equations (not indexed to BSA) was similar (73%, 73%, 74%, and 73% respectively) for a breakpoint value of 90 mL/min for GFR. At this value, the concordance rate between mGFR and MDRD indexed to BSA was significantly lower (65%, P<0.05). Using 70 mL/min of GFR as the breakpoint value, all equations had similar concordance rates with mGFR (with or without indexation to BSA).
Conclusion:
CKD-EPI equation has the same concordance with GFR and with CG when used for drug dosing.
Related Concept Videos
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations