Using Q Suture to Enhance Resistance to Gap Formation and Tensile Strength of Repaired Flexor Tendons
Published on: June 3, 2020
Symmetric Peripheral Running Sutures are Superior to Asymmetric Peripheral Running Sutures for Increasing the Tendon
N Takeuchi1, T Okada1, N Kozono1
1* Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, Japan.
Background:
The fatigue strength of three peripheral suture techniques for flexor tendon repair was compared by cyclic loading of the repairs in the porcine flexor digitorum tendon.
Methods:
Thirty-six tendons were sutured using only peripheral sutures with 6-0 Nylon. An initial cyclic load of 10 N for 500 cycles was applied and increased by 10 N for an additional 500 cycles at each new load until rupture.
Results:
The fatigue strength of the symmetric running peripheral suture was 85.0% and 144.8% greater than that of the two kinds of the asymmetric running peripheral sutures.
Conclusions:
Symmetric running sutures can enhance the suture strength and appears to be a useful technique for increasing the strength of the peripheral suture.