SU-E-J-105: Evaluating Auto-Contouring of Prostate KV Conebeam CTs
A Godley1, L Sheplan Olsen1, K Stephans1
1Cleveland Clinic, Cleveland, OH.
Evaluating auto-contouring for adaptive radiotherapy, this study found V70 best assesses rectum and bladder suitability, while D100 is most discerning for prostate. Dice
Area of Science:
- Radiation Oncology
- Medical Physics
- Image-guided radiotherapy
Background:
- Online adaptive radiotherapy requires accurate auto-contouring of daily kV conebeam CTs (kVCBCT).
- Assessing the suitability of auto-contouring algorithms is crucial for effective adaptive planning.
Purpose of the Study:
- To identify the most effective geometric and dosimetric measures for evaluating kVCBCT auto-contouring algorithms in prostate adaptive radiotherapy.
- To compare the performance of auto-contouring with physician-generated contours.
Main Methods:
- Six prostate cancer patients undergoing IMRT were included.
- kV conebeam CT (kVCBCT) contours were generated using ABAS software and by a physician.
- Prostate D100, D98, and mean dose were assessed.
- Rectal and bladder V70 (volume receiving 70% of the prescription dose) and mean dose were evaluated.
- Dice's Coefficient (DC) and a restricted DC (rDC) were calculated.
Main Results:
- Prostate accuracy is best assessed by D100, with no correlation to Dice's Coefficient (DC).
- Mean dose is not a reliable indicator of contour suitability for any organ.
- Rectal and bladder V70 showed high sensitivity to contour suitability, despite no correlation with DC.
- Restricted Dice's Coefficient (rDC) demonstrated optimal correlation with V70 for rectum and bladder.
Conclusions:
- V70 is the most sensitive metric for rectal and bladder contour suitability in adaptive radiotherapy.
- D100 is the most discerning metric for prostate contouring due to treatment margins.
- Dice's Coefficient and mean dose are not suitable for assessing contour accuracy.
- Restricted Dice's Coefficient (rDC) can serve as an alternative to V70, potentially simplified by proximity to the prostate contour.
More Related Videos
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography