Bolus Insulin Dose Error Distributions Based on Results From Two Clinical Trials Comparing Blood Glucose Monitoring
Scott Pardo1, Nancy Dunne1, David A Simmons1
11 Ascensia Diabetes Care, Parsippany, NJ.
Blood glucose monitoring systems (BGMSs) impact insulin dosing accuracy. The CONTOUR®NEXT EZ and CONTOUR®NEXT BGMSs demonstrated significantly smaller insulin dose errors compared to other systems, highlighting the importance of BGMS accuracy in diabetes management.
Area of Science:
- Diabetes Technology
- Clinical Chemistry
- Medical Device Evaluation
Background:
- Previous clinical trials assessed fingertip capillary blood samples using blood glucose monitoring systems (BGMSs) and a YSI glucose analyzer.
- Post hoc analyses calculated hypothetical insulin doses based on BGMS measurements to compare dosing errors.
Purpose of the Study:
- To evaluate the accuracy of different blood glucose monitoring systems (BGMSs) in determining insulin dose errors.
- To compare the range of insulin dose errors across various BGMSs in two clinical trials.
Main Methods:
- Hypothetical premeal bolus insulin doses were calculated for a standardized individual (60-g carbohydrate meal, 100-mg/dL target glucose).
- Insulin sensitivity and carbohydrate ratio were adjusted to account for potential BGMS measurement errors.
- Dosing error was defined as the difference between insulin doses calculated using BGMS readings and a reference YSI glucose analyzer.
Main Results:
- In Clinical Trial 1, the CONTOUR®NEXT EZ BGMS (EZ) showed a 95% dose error range of -0.9 to 0.5 units.
- In Clinical Trial 2, the CONTOUR®NEXT BGMS (CN) exhibited a 95% dose error range of -0.7 to 1.7 units.
- Both EZ and CN BGMSs demonstrated statistically significantly smaller insulin dose error ranges compared to all other evaluated BGMSs (P <0.0001).
Conclusions:
- The CONTOUR®NEXT EZ and CONTOUR®NEXT BGMSs yielded statistically significantly smaller insulin dose errors in post hoc analyses.
- Variations in BGMS accuracy can lead to clinically significant differences in insulin dosing recommendations.
More Related Videos
08:32Studying the Hypothalamic Insulin Signal to Peripheral Glucose Intolerance with a Continuous Drug Infusion System into the Mouse Brain
Published on: January 4, 2018
07:30Homogeneous Time-resolved Förster Resonance Energy Transfer-based Assay for Detection of Insulin Secretion
Published on: May 10, 2018
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Dosage Regimen: Individualization
Errors occurring during blood pressure monitoring
Several factors...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...