Related Experiment Video
Updated: Feb 28, 2026

Effects of Surgical Masks on Cardiopulmonary Function in Healthy Subjects
Published on: February 12, 2021
Validation of masks for determination of V̇O2 max in horses exercising at high intensity
R H Sides1, R Kirkpatrick1, E Renner1
1Department of Veterinary Clinical Sciences, Washington State University, Pullman, Washington, USA.
Background:
The need for a horse to be ridden while wearing a measurement device that allows unrestricted ventilation and gas exchange has hampered accurate measurement of its maximal oxygen consumption (V̇O2 max) under field conditions.
Objectives:
Design and validate a facemask with the potential to measure V̇O2 max accurately in the field.
Study Design:
Experiment with 6 × 6 Latin square design.
Methods:
Two variations of a mask and associated electronic control module (ECM) were designed to enable breath-by-breath measurement of airflows through two 7.8 cm diameter pneumotachometers located 7.5 cm in front of each narus. The ECM was comprised of an analogue-to-digital converter and a lithium-ion battery that provided power and signal filtering to the pneumotachometers and an oxygen sensing cell, and powered a pump connected to gas sampling ports between the nares and pneumotachometers. Airflow and oxygen content of inspired and expired gases were recorded through the ECM and electronically transferred to a notebook. V̇O2 was determined from these recordings using a customised software program. Mask B encased the lower jaw. Mask R left the jaw free so the horse could wear a bit if ridden. V̇O2 max and arterial blood gases were measured in 6 horses during multiple treadmill tests. Each mask was worn twice and results compared to those from an established open flow-through system (O) by ANOVA-RM (P<0.05). System utility was evaluated using the intraclass correlation coefficient of 4 independent raters.
Results:
Blood gases and V̇O2 max (151.9±7.0 [mean±s.d.; O], 151.5±9.6 [B], 149.5±7.5 [R] ml/[kg.min]) were not different between masks. V̇O2 max measures were reproducible for each mask. Intraclass correlation coefficient between raters = 0.99.
Main Limitations:
Some rebreathing of expired air from mask dead space.
Conclusion:
Masks capable of measuring V̇O2 max during treadmill exercise were developed, tested and found to be accurate. Mask R has potential application to measurement of V̇O2 max under field conditions.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:

