A Fiber Bragg Grating Sensor for Radial Artery Pulse Waveform Measurement
IEEE Transactions on Bio-Medical Engineering
|July 7, 2017
Summary
A novel optical sensor using fiber Bragg grating (FBG) and lever amplification accurately measures radial artery pulse waveforms. This high-sensitivity system offers improved clinical diagnosis for cardiovascular diseases.
Area of Science:
- Biomedical Engineering
- Optical Sensing Technologies
- Cardiovascular Diagnostics
Background:
- Pulse waveform analysis is crucial for clinical examination and diagnosing cardiovascular diseases.
- High-fidelity radial artery pulse waveforms are vital for estimating central aortic pressure, a predictor of cardiovascular risk.
- Optimal pulse waveform acquisition requires examination from multiple locations due to the radial artery's cylindrical nature.
Purpose of the Study:
- To design and experimentally validate a novel optical sensor for multilocation radial artery pulse waveform measurement.
- To leverage fiber Bragg grating (FBG) and a lever amplification mechanism for enhanced sensitivity and electromagnetic interference immunity.
- To assess the feasibility of optical sensing for physiological measurements in clinical applications.
Main Methods:
- Development of an optical sensing system integrating a fiber Bragg grating (FBG) sensor with a lever amplification mechanism.
- Characterization of the FBG sensor's sensitivity, achieving 8.236 nm/N, comparable to electrical sensors.
- Experimental validation of the sensor's performance by measuring radial artery pulse waveforms at various positions and depths, guided by physicians.
Main Results:
- The FBG-based optical sensor demonstrated high sensitivity and immunity to electromagnetic interference.
- The system provided accurate radial artery pulse waveform measurements, enabling extraction of key characteristic parameters.
- Experimental validation confirmed the sensor's effectiveness in capturing pulse waveforms at different locations and depths.
Conclusions:
- The developed optical sensing system is highly feasible for physiological measurements.
- The FBG sensor offers a promising tool for accurate radial artery pulse waveform measurement in clinical settings.
- This technology supports advanced diagnostics for cardiovascular diseases through precise pulse analysis.
Related Concept Videos
Assessment of radial pulse
1.6K
Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
1.6K
Assessment of apical radial pulse
1.4K
Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
1.4K
Pulse
2.4K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
2.4K
Equipments Used To Measure Blood Pressure
3.8K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.8K
Special considerations while measuring pulse
1000
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
1000
Assessment of blood pressure in brachial artery(one-step method)
1.3K
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
1.3K