Related Experiment Video
Updated: Feb 26, 2026

Author Spotlight: A Simple and Cost-Effective Method for Leukocyte Analysis in Semen
Published on: January 19, 2024
Prostate-specific antigen concentration in vaginal fluid after exposure to semen
Andrzej Kulczycki1, Ilene Brill2, Margaret Christine Snead3
1Department of Health Care Organization and Policy, University of Alabama at Birmingham, Birmingham, AL, USA.
Objective:
Prostate-specific antigen (PSA) is the best established biomarker of semen exposure. PSA in vaginal fluid returns to pre-exposure concentrations within 24-48 h, but the speed of decay during the first 10 h is unknown. We sought to determine how fast PSA concentrations decline during the first 10 h after exposure to semen.
Study Design:
Women in the 50 enrolled couples were intravaginally inoculated with 10, 20, 100 and 200 microl of their partner's semen and then collected vaginal swabs immediately after, 30 min, 4 h and 10 h after exposure. Forty-seven sets of samples were tested for PSA. Mixed linear models for repeated measures examined the association between log-transformed PSA values and sampling time and semen exposure volume. Sensitivity analyses excluded data from nonabstainers. Fixed-effect estimates from the statistical models were graphed.
Results:
PSA values were highest at 200 microl inoculation volumes and at earlier post-exposure time points, then decline steadily. The lowest inoculation volume (10 microl) corresponded to the smallest concentration of PSA throughout the post-inoculation time points. Average PSA levels return to clinically non-detectable levels within 10 h only at the lowest semen exposures. The PSA decay curve assumes a very similar profile across all time points and semen amounts.
Conclusions:
The PSA decay curve is similar for varying semen exposure volumes, with average PSA concentrations remaining above clinical thresholds 10 h after exposure at all except the very smallest semen exposure levels. PSA is an objective marker of recent exposure to semen, permitting such detection with high accuracy.
Implications:
This study clarifies how PSA values vary at different semen exposure levels and time points during the first 10 h post-exposure. Future contraceptive studies that use PSA as a semen biomarker will be better informed about PSA concentrations at different sampling times and exposure amounts.
More Related Videos
05:44Medium-throughput Screening Assays for Assessment of Effects on Ca2+-Signaling and Acrosome Reaction in Human Sperm
Published on: March 1, 2019
13:19Microarray-based Identification of Individual HERV Loci Expression: Application to Biomarker Discovery in Prostate Cancer
Published on: November 2, 2013
Related Concept Videos
Sperm Structure and Semen Composition
Accessory Glands of the Male Reproductive System
The epididymis is a small, comma-shaped organ located at the back of each testicle. The epididymis can be divided into three main parts: the head, body, and tail. The head of the epididymis...