Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Implications of phase ratio for maximizing peak capacity in comprehensive two-dimensional gas chromatography
Brendon A Parsons1, David K Pinkerton1, Robert E Synovec1
1Department of Chemistry, Box 351700, University of Washington, Seattle, WA 98198, USA.
Abstract:
The relationship between the phase ratio, β, of the primary (1D) and secondary (2D) separation dimensions of comprehensive two-dimensional (2D) gas chromatography (GC×GC) separations, and the implications of β on realization of maximal 2D peak capacity, nc,2D, are examined. A GC×GC chromatographic system with time-of-flight mass spectrometry, TOFMS, was otherwise held constant for the separation of a multi-component test mixture spanning a range of chemical functionalities, while only the β of the two analytical columns were changed, 1β for 1D and 2β for 2D. Six column sets were studied using common, commercially available β values. The β ratio, βR=1β/2β, is defined as a quantitative metric to facilitate this study. It is demonstrated that βR plays a key role in maximizing nc,2D. Overall, βR substantially affected nc,2D by influencing retention factors on the 2D column, 2k, and thereby changing the modulation period, PM, necessary for proper 2D column separations. The necessary changes to PM modify the modulation ratio, MR, which affects the 1D column peak widths and 1nc due to the impact of undersampling. Through changes to 1β, the range of 2k can be controlled, with subsequent effects to both 2nc and 1nc. These effects were opposite in direction, such that improvements to 2nc may result in declines in 1nc. It is observed that due to the pseudo-isothermal nature of the 2D separation, there are diminishing returns to extending the 2nc at the cost of 1nc. In this particular study, column set 3 (1D: 20m length, 250μm i.d., 0.25μm film; 2D: 2m, 180μm i.d., 0.2μm film; βR=1.11) with a PM of 3s provided the highest theoretical nc,2D of ∼8200, though this was at a relatively low MR of ∼1.8. Column set 2 (1D: 20m length, 250μm i.d., 0.5μm film; 2D: 2m, 180μm i.d., 0.2μm film; βR=0.56) with a PM of 1.5s provided a high theoretical nc,2D of ∼5800, at a much higher MR of ∼3.7. Though column set 2 had a lesser total peak capacity than column set 3, its higher MR suggests that by improving the 1D column efficiency (i.e., narrowing the 1D column peak widths) to improve 1nc, can result in an increased theoretical nc,2D.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Chromatographic Methods: Terminology
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Mass Analyzers: Common Types