Related Experiment Video
Updated: Feb 25, 2026

Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Patient-Reported Dyspnea Correlates Poorly with Aerobic Exercise Capacity Measured During Cardiopulmonary Exercise
Dany Gaspard1, Jonathan Kass1, Stephen Akers1
1Division of Pulmonary and Critical Care Medicine, Cooper University Hospital, Camden, NJ, USA.
Background:
Patient-reported dyspnea plays a central role in assessing cardiopulmonary disease. There is little evidence, however, that dyspnea correlates with objective exercise capacity measurements. If the correlation is poor, dyspnea as a proxy for objective assessment may be misleading.
Objective:
To compare patient's perception of dyspnea with maximum oxygen uptake (MaxVO2) during cardiopulmonary exercise testing (CPET).
Methods:
Fifty patients undergoing CPET for dyspnea evaluation were studied prospectively. Dyspnea assessment was measured by a metabolic equivalent of task (METs) table, Mahler Dyspnea Index, Borg Index, number of blocks walked, and flights of stairs climbed before stopping due to dyspnea. These descriptors were compared to MaxVO2.
Results:
MaxVO2 showed low correlation with METs table (r = 0.388, p = 0.005) and no correlation with Mahler Index (r = 0.24, p = 0.093), Borg Index (r = -0.017, p = 0.905), number of blocks walked (r = 0.266, p = 0.077) or flights of stairs climbed (r = 0.188, p = 0.217). When adjusted for weight (maxVO2/kg), there was significant correlation between MaxVO2 and METs table (r = 0.711, p < 0.001), moderate correlation with blocks walked (r = 0.614, p < 0.001), and low correlation with Mahler Index (r = 0.488 p = 0.001), Borg Index (r = -0.333 p = 0.036), and flights of stairs (r = 0.457 p = 0.004). Subgroup analysis showed worse correlation when patients with normal CPET were excluded (12/50 excluded). Patients with BMI < 30 had no correlation between Max VO2 and the assessment methods, while patients with BMI > 30 had moderate correlation between MaxVO2 and METs table (r = 0.568, p = 0.002).
Conclusion:
Patient-reported dyspnea correlates poorly with MaxVO2 and fails to predict exercise capacity. Reliance on reported dyspnea may result in suboptimal categorization of cardiopulmonary disease severity.
More Related Videos
07:10Home-Based Prescribed Pulmonary Exercise in Patients with Stable Chronic Obstructive Pulmonary Disease
Published on: August 24, 2019
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Respiratory Volumes and Capacities I
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...