Purpose:
To compare the capability of amide proton transfer-weighted (APTw) imaging, diffusion-weighted imaging (DWI), and FDG-PET/CT for the differentiation of malignant from benign pulmonary nodules.
Materials And Methods:
In all, 82 consecutive patients with pulmonary nodules underwent APTw imaging and DWI with a 3T system, and FDG-PET/CT. All nodules were divided as either malignant (n = 49) or benign (n = 39) groups based on pathological and follow-up examinations. To evaluate the capability for differentiation of malignant from benign nodules, magnetization transfer ratio asymmetry (MTRasym )(3.5ppm) on APTw imaging, apparent diffusion coefficient (ADC), and maximum value of standard uptake value (SUVmax ) were assessed. Receiver operating characteristic (ROC) analyses were performed to computationally determine each feasible threshold value. Next, McNemar's test was used for comparing diagnostic performance with each other as well as with a combination of the significant factors determined by multivariate logistic regression analysis.
Results:
Although sensitivity of ADC was significantly higher than that of MTRasym (3.5 ppm) (P = 0.002) and SUVmax (P = 0.004), specificity of MTRasym (3.5 ppm) and SUVmax was significantly higher than that of ADC (P < 0.05). Sensitivity of combined MTRasym (3.5ppm) with SUVmax was significantly higher than that of MTRasym (3.5ppm) (P = 0.001) and SUVmax (P = 0.002) alone. Moreover, specificity and accuracy of combined MTRasym (3.5ppm) with SUVmax were significantly higher than that of ADC (specificity: P = 0.002, accuracy: P = 0.008).
Conclusion:
APTw imaging appears to be as useful as DWI and FDG-PET/CT for differentiation of malignant from benign nodules.
Level Of Evidence:
2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1013-1021.
More Related Videos
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET