Impact of Simulator-Based Training in Focused Transesophageal Echocardiography: A Randomized Controlled Trial
Andreas Bloch1, Robert von Arx, Reto Etter
1From the *Department of Intensive Care Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; †Department of Intensive Care Medicine, Spitalzentrum Biel, Biel, Switzerland; ‡Department of Anesthesiology and Pain Therapy, Inselspital, Bern University Hospital, University of Bern, Switzerland; and §Clinical Trial Unit Bern, Department of Clinical Research, University of Bern, Bern, Switzerland.
Background:
The aim of the study was to determine if training in transesophageal echocardiography (TEE) using a TEE simulator improves the ability of novice operators to perform and interpret a focused critical care TEE.
Methods:
In this prospective, randomized, controlled study with blinded outcome assessment, 44 intensive care unit trainees were randomly assigned to a control group receiving 4 hours of lecture-based training only, or an intervention group which was additionally trained for 4 hours using a TEE simulator. After the training intervention, each participant performed 2 TEEs in intensive care unit patients which were evaluated by blinded assessors. The imaging quality of TEEs was measured using a predefined examination quality score ranging from 0 to 100 points. The correct quantification of pathologies and the interpretation of the TEEs were evaluated by blinded assessors using focused and comprehensive expert TEEs as comparators.
Results:
A total of 114 TEEs were assessed. The mean examination quality score was 55.9 (95% confidence interval [CI], 50.3-61.5) for TEEs of the control group, 75.6 (95% CI, 70.1-81.0) for TEEs of the intervention group, and 88.5 (95% CI, 79.3-97.7) for TEEs in the expert group. The multiple comparisons revealed significant differences between all groups (19.7 [95% CI, 12.8-26.6], P < .001 for intervention versus control; 32.6 [95% CI, 23.0-42.3], P < .001 for expert versus control; 12.9 [95% CI, 3.4-22.5], P = .008 for expert versus intervention). Substantial agreement of the quantification and interpretation ratings of basic TEEs by the intervention (86.7% for quantification and 97.1% for interpretation) or expert group (93.2% for quantification and 98.4% for interpretation) with blinded assessors was detected. The control groups TEEs agreed less (75.6% for quantification and 91.8% for interpretation).
Conclusions:
Simulation-based TEE training improves the ability of novice operators to perform a focused critical care TEE in comparison to lecture-based education only. After 8 hours of simulator and lecture-based training, the majority of TEEs of novices are of sufficient quality for clinical use. Furthermore, a substantial skill level in correct quantification and interpretation of imaging is achieved.
More Related Videos
05:04Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
06:50Troubleshooting FoCUS Image Acquisition: Patient Positioning, Transducer Manipulation, and Image Optimization
Published on: March 3, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...