Related Experiment Video
Updated: Feb 23, 2026

High-Temperature and High-Pressure In situ Magic Angle Spinning Nuclear Magnetic Resonance Spectroscopy
Published on: October 9, 2020
Imaging the spatial distribution of radiofrequency field, sample and temperature in MAS NMR rotor
Hiroki Nagashima1, Julien Trébosc1, Olivier Lafon2
1Univ. Lille, CNRS, ENSCL, UMR 8181, UCCS, Unité de Catalyse et de Chimie du Solide, 59000 Lille, France.
Abstract:
We investigate using nutation experiments the spatial distribution of radiofrequency (rf) field, sample, temperature and cross-polarization transfer efficiency in 1.3 mm rotor. First, two-dimensional (2D) 1H nutation experiments on silicone thin cylinders in the presence of B0 field gradient generated by shim coils are used to image the spatial distribution of rf field inside the rotor. These experiments show that the rf field is asymmetrical with respect to the center of the rotor. Moreover, they show the large inhomogeneity that still remains across the sample when using spacers, and that even in this case, the rf-field close to the drive cap is decreased to ca. only 20% of its maximum value. Such 2D nutation experiment in the presence of B0 field gradient are also employed to demonstrate the migration of adamantane sample from the center of the rotor to its ends during Magic-Angle Spinning (MAS). Furthermore, 2D 1H nutation experiments on nickelocene exhibiting temperature-dependent isotropic chemical shift provides insights into the temperature distribution inside rotor. Finally three-dimensional (3D) 1H → 13C Cross-Polarization under MAS (CPMAS) nutation experiment indicates that only nuclei subject to the largest rf field contribute to the CPMAS transfer, when using rf field of constant amplitude on both channels. Such high selectivity allows the determination of accurate dipolar coupling constants in the Cross-Polarization with Variable Contact (CP-VC) experiment under fast MAS, at the expense of low sensitivity. Conversely when using ramped-amplitude on the 1H channel during the CPMAS transfer, nuclei subject to smaller rf field contributes to the transfer, which increases the sensitivity of CPMAS experiment but does not allow an accurate determination of dipolar coupling constants using CP-VC experiment.
More Related Videos
14:55Atomic Scale Structural Studies of Macromolecular Assemblies by Solid-state Nuclear Magnetic Resonance Spectroscopy
Published on: September 17, 2017
06:42Cryogenic Sample Loading into a Magic Angle Spinning Nuclear Magnetic Resonance Spectrometer that Preserves Cellular Viability
Published on: September 1, 2020
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Atomic Nuclei: Nuclear Spin State Population Distribution
NMR Spectrometers: Resolution and Error Correction
Atomic Nuclei: Magnetic Resonance
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
NMR Spectrometers: Overview