Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses
Richard N McNeely1, Eric Pazo1, Andrew Spence1
1From Cathedral Eye Clinic (McNeely, Pazo, Spence, Richoz, J.E. Moore), Belfast, and the Biomedical Sciences Research Institute (McNeely, Pazo, Nesbit, T.C.B. Moore, J.A. Moore), University of Ulster, Coleraine, Northern Ireland, United Kingdom.
Purpose:
To compare the 12-month postoperative quality of vision and visual performance of 2 different refractive rotationally asymmetric multifocal intraocular lenses (IOLs).
Setting:
Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom.
Design:
Retrospective case series.
Methods:
Refractive lens exchange (RLE) patients were divided into 2 groups. Group A comprised eyes receiving a Lentis Mplus LS-312 MF30 IOL and Group B, eyes receiving a Lenstec SBL-3 IOL. Refraction, uncorrected (UDVA) and corrected distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, distance-corrected intermediate and near (DCNVA) visual acuities, and quality of vision were evaluated preoperatively and up to 12 months postoperatively.
Results:
Each group comprised 90 eyes. Both groups had a high level of quality of vision 12 months postoperatively with no significant difference between the 2 groups (P = .919). There was no significant between-group difference in mean monocular and binocular UDVA, monocular UIVA, or monocular UNVA. Group B had statistically significantly better mean monocular DCNVA (P = .049), binocular UNVA (P = .011), and binocular DCNVA (P = .035). Group B had a higher percentage of complete spectacle independence.
Conclusions:
Both refractive rotationally asymmetric multifocal IOLs provided an excellent level of quality of vision 12 months postoperatively. Both IOL models restored distance, intermediate, and near visual function; however the IOLs in Group B provided better near visual performance.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Properties of Enantiomers and Optical Activity
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...