Comparing Non-Invasive and Fluorescein Tear Break-Up Time in a Pre-Operative Refractive Surgery Population:
Rebecca Cairns1,2, Richard N McNeely1, Mark C M Dunne2
1Cathedral Eye Clinic, Belfast BT1 2LS, UK.
Journal of Clinical Medicine
|August 28, 2025
Summary
Fluorescein break-up time (FBUT) systematically underestimates tear stability compared to non-invasive break-up time (NIBUT). The standard 10-second threshold is not applicable to both methods for assessing tear film stability.
Area of Science:
- Ophthalmology
- Optometry
- Tear Film Dynamics
Background:
- Fluorescein break-up time (FBUT) is a common but potentially biased method for assessing tear film stability.
- Instilling fluorescein can alter tear film dynamics, affecting test validity and repeatability.
- Non-invasive break-up time (NIBUT) offers a less biased alternative for evaluating tear film stability.
Purpose of the Study:
- To compare Fluorescein Break-Up Time (FBUT) and Non-Invasive Break-Up Time (NIBUT) in patients undergoing pre-operative refractive surgery assessment.
- To evaluate the clinical applicability of the conventional 10-second threshold for tear break-up time in both methods.
- To inform pre-operative patient counseling regarding dry eye disease and refractive surgery risks.
Main Methods:
- Analysis of data from consecutive participants attending an ophthalmology clinic for refractive surgery pre-operative assessment.
- Performance of both Non-Invasive Break-Up Time (NIBUT) and Fluorescein Break-Up Time (FBUT) tests.
- Statistical comparisons using Wilcoxon signed-rank and Mann-Whitney U tests, with Spearman's rank correlation for demographic analysis.
Main Results:
- Median NIBUT was 12.5-14.6 seconds, while median FBUT was 6-7 seconds for both eyes.
- A statistically significant difference (p < 0.001) was observed between NIBUT and FBUT measurements.
- FBUT values were consistently lower than NIBUT values, indicating underestimation of tear stability.
Conclusions:
- The standard 10-second threshold for tear break-up time is not uniformly applicable to both FBUT and NIBUT.
- FBUT systematically underestimates tear film stability compared to NIBUT.
- Accurate assessment of tear film stability using appropriate methods is crucial for pre-operative refractive surgery evaluations.