Related Experiment Video
Updated: Feb 22, 2026

A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis
Published on: September 10, 2014
Sensitive electrochemical detection of DNA damage based on in situ double strand growth via hybridization chain
Misha Liu1, Jinjin Xu1, Fan Yang1
1Shanghai Key Laboratory of Chemical Assessment and Sustainability, School of Chemical Science and Engineering, College of Environmental Science and Technology, Tongji University, 1239 Siping Road, Shanghai, 200092, China.
Abstract:
Detection of DNA damage caused by ∙OH or radiation has led to rapidly growing interest in the fields of drug development, biochemistry, clinic diagnostics, and environmental evaluation. Electrochemical methods have been applied for DNA damage detection because of their fast and sensitive response. However, most of the electrochemical methods for DNA damage detection commonly require immobilization of the strands on the electrode surface. In the present work, sensitive electrochemical monitoring of DNA damage was realized successfully on the basis of in situ DNA chain growth by use of a hybridization chain reaction (HCR) technique. By use of [Ru(NH3)6]3+ as the signal probe and the Fenton reaction as the ∙OH generator, ultrasensitive detection of DNA damage induced by ∙OH was realized successfully through differential pulse voltammetry with a linear relationship of ∙OH concentration from 15 to 750 pM and a detection limit of 12 pM. Furthermore, environmental DNA-damaging UV light was tested as the lesion source to demonstrate the practicability and reliability of the proposed HCR-based amplified signal method for DNA damage detection. By integrating the HCR technique with an electrochemical method, we provide a promising alternative approach to extend the applications of electrochemical methods in bioanalytical detection of DNA damage. Graphical abstract Sensitive electrochemical monitoring of DNA damage has been realized successfully on the basis of in situ DNA chain growth by use of hybridization chain reaction (HCR). Detection of DNA damage caused by ∙OH was realized successfully through differential pulse voltammetry with a linear relationship of ∙OH concentration from 15 to 750 pM and a detection limit of 12 pM.
More Related Videos
08:56In vitro Assembly of Semi-artificial Molecular Machine and its Use for Detection of DNA Damage
Published on: January 11, 2012
13:10Detection and Visualization of DNA Damage-induced Protein Complexes in Suspension Cell Cultures Using the Proximity Ligation Assay
Published on: June 9, 2017
Related Concept Videos
Homologous Recombination
Overview of DNA Repair
Chemically...
Fixing Double-strand Breaks