The effect of Mg and Sr on the crystallinity of bones evaluated through Raman spectroscopy and laser ablation-ICPMS
Yu-Ki Tanaka1, Nobuyuki Yajima, Masahiro Okada
1Laboratory for Planetary Sciences, Kyoto University, Kitashirakawa-oiwakecho, Sakyo-ku, Kyoto, 606-8501, Japan. tanaka.yuuki.78v@kyoto-u.jp.
Abstract:
We investigated the possible linkage between the crystallinity and elemental ratios (Mg/Ca and Sr/Ca) of the femoral cortical bones of rats with chronic kidney disease (CKD) or diabetes mellitus (DM). The Mg/Ca and Sr/Ca ratios were measured by using the laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) technique and the crystallinity was evaluated by Raman spectroscopy on the same sample slice. The measured crystallinity varied significantly along the radial direction, reflecting the heterogeneities in the Mg/Ca ratio for the bone samples. For the endosteal cortical bone of CKD rats, the Mg/Ca ratio became higher. This is explained by the increase of the abundance of Mg in the bone, possibly due to the higher absorption efficiency of Mg in the intestine or due to the lower excretion efficiency of Mg from the kidney. For areas with a higher Mg/Ca ratio, the crystallinity of the bone was significantly more degraded than that for areas with a lower Mg/Ca ratio, suggesting that the substitution of Ca by Mg induced the deterioration of the crystallinity of hydroxyapatite (HAp). In addition, the measured Mg/Ca and Sr/Ca ratios of the bone were positively correlated with those found in serum samples. The data obtained here demonstrated that the metabolic alterations for inorganic elements caused the ionic substitutions of Ca by foreign cationic ions, and that the contents of foreign ions in the bone greatly affected the crystallinity of HAp.
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences