Related Experiment Video
Updated: Feb 21, 2026

Cardiac Magnetic Resonance Imaging at 7 Tesla
Published on: January 6, 2019
Cardiac magnetic resonance imaging using wideband sequences in patients with nonconditional cardiac implanted
Duc H Do1, Vaughn Eyvazian1, Aileen J Bayoneta2
1UCLA Cardiac Arrhythmia Center, UCLA Health System, David Geffen School of Medicine at UCLA, Los Angeles, California.
Background:
Magnetic resonance imaging (MRI) has been performed safely in patients without MRI-conditional cardiac implantable electronic devices (CIEDs), but experience specifically with cardiac magnetic resonance imaging (CMR) is limited in this patient population.
Objective:
Evaluate the safety of CMR in non-MRI-conditional CIEDs and the interpretability of images using wideband sequences.
Methods:
We performed 114 consecutive CMR studies in 111 patients (mean age 59 ± 14 years, with 12 pacemakers, 73 implantable cardioverter defibrillators, 29 biventricular defibrillators) using a wideband pulse sequence for late gadolinium enhancement (LGE) imaging. A standardized protocol for device management and patient monitoring was followed. Patients were evaluated for major clinical adverse events and device parameter changes immediately after CMR and at clinical follow-up.
Results:
In total, 111 CMR studies were completed successfully. There were no patient deaths, new arrhythmias, immediate generator or lead failures, electrical resets, or pacing capture failures in dependent patients. Right atrial, right ventricular, and left ventricular lead impedances were significantly lower post CMR, with median differences -7 Ω (interquartile range [IQR] -20 to 0 Ω; P < .0001), 0 Ω (IQR -19 to 0 Ω; P = .0001), and -10 Ω (IQR -30 to 0 Ω; P = .023), respectively. These changes persisted through the follow-up period, with median differences -18.5 Ω (IQR -41 to -66 Ω; P = .007), -19 Ω (IQR -44 to -7 Ω; P = .006), and -30 Ω (IQR -130 to 0 Ω; P = .003), respectively. Ninety-seven studies (87%) had no artifact limiting interpretation.
Conclusions:
CMR can be performed safely in non-MRI-conditional CIEDs using a standardized protocol. Use of a wideband pulse sequence for LGE imaging yields a high rate of studies unaffected by artifact.
More Related Videos
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...