Related Experiment Video
Updated: Aug 15, 2026

Quantitative Autonomic Testing
Published on: July 19, 2011
Hemodynamic parameters and baroreflex sensitivity during head-up tilt test in patients with neurally mediated syncope
Sung Ho Lee1, Ji Hyun Yang2, Hye Ran Yim3
1Division of Cardiology, Department of Internal Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Background:
We aimed to investigate differences in hemodynamic parameters and the role of baroreflex sensitivity (BRS) in patients with a history of neurally mediated syncope (NMS) compared with a control group.
Methods:
Hemodynamic parameters and BRS were continuously measured noninvasively using a Finometer at rest and during passive head-up tilt test (HUT) in patients with a history of NMS (n = 55) and a control group (n = 77). The tilting period was divided into pretest (resting supine position), initial (first 3 minutes of tilting), last (last 3 minutes of tilting), and recovery (3 minutes after tilting was complete) periods.
Results:
Decrease in systolic blood pressure (- 14.7 ± 15.7 mm Hg vs - 7.6 ± 14.3 mm Hg, P < 0.01) was more prominent and increase in total systemic peripheral resistance was significantly smaller (67.6 ± 418.7 dyn.s/cm5 vs 189.4 ± 261.0 dyn.s/cm5 , P = 0.04) from the initial to the last period of HUT in the patient group compared with the control group. BRS was significantly higher during the pretest period (20.1 ± 10.9 ms/mm Hg vs 13.0 ± 8.1 ms/mm Hg, P < 0.01) in the patient group, while the decrease in BRS from the pretest to the initial period was greater (-8.5 ± 6.0 ms/mm Hg vs - 3.2 ± 4.1 ms/mm Hg, P = 0.01).
Conclusions:
Dysfunctional BRS in response to orthostatic stress might be involved in pathological autonomic cardiac modulation of NMS.
More Related Videos
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure