Related Experiment Video
Updated: Aug 12, 2026

Intense Pulsed Light for the Treatment of Dry Eye Owing to Meibomian Gland Dysfunction
Published on: April 1, 2019
Randomized Trial of Desktop Humidifier for Dry Eye Relief in Computer Users
Michael T M Wang1, Evon Chan, Linda Ea
11Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand 2Department of Optometry and Vision Science, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand *jp.craig@auckland.ac.nz.
Significance:
Dry eye is a frequently reported problem among computer users. Low relative humidity environments are recognized to exacerbate signs and symptoms of dry eye, yet are common in offices of computer operators. Desktop USB-powered humidifiers are available commercially, but their efficacy for dry eye relief has not been established.
Purpose:
This study aims to evaluate the potential for a desktop USB-powered humidifier to improve tear-film parameters, ocular surface characteristics, and subjective comfort of computer users.
Methods:
Forty-four computer users were enrolled in a prospective, masked, randomized crossover study. On separate days, participants were randomized to 1 hour of continuous computer use, with and without exposure to a desktop humidifier. Lipid-layer grade, noninvasive tear-film breakup time, and tear meniscus height were measured before and after computer use. Following the 1-hour period, participants reported whether ocular comfort was greater, equal, or lesser than that at baseline.
Results:
The desktop humidifier effected a relative difference in humidity between the two environments of +5.4 ± 5.0% (P < .001). Participants demonstrated no significant differences in lipid-layer grade and tear meniscus height between the two environments (all P > .05). However, a relative increase in the median noninvasive tear-film breakup time of +4.0 seconds was observed in the humidified environment (P < .001), which was associated with a higher proportion of subjects reporting greater comfort relative to baseline (36% vs. 5%, P < .001).
Conclusions:
Even with a modest increase in relative humidity locally, the desktop humidifier shows potential to improve tear-film stability and subjective comfort during computer use.Trial registration no: ACTRN12617000326392.
More Related Videos
06:29Effect of Artificial Tear Formulations on the Metabolic Activity of Human Corneal Epithelial Cells after Exposure to Desiccation
Published on: May 2, 2020
06:29Comparing Objective Conjunctival Hyperemia Grading and the Ocular Surface Disease Index Score in Dry Eye Syndrome During COVID-19
Published on: May 25, 2022