Related Experiment Video
Updated: Feb 20, 2026

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Grid mapping: a novel method of signal quality evaluation on a single lead electrocardiogram
Yanjun Li1,2, Xiaoying Tang3
1Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, The Ministry of Industry and Information Technology, School of Life Science, Beijing Institute of Technology, Beijing, 100081, China.
Abstract:
Diagnosis of long-term electrocardiogram (ECG) calls for automatic and accurate methods of ECG signal quality estimation, not only to lighten the burden of the doctors but also to avoid misdiagnoses. In this paper, a novel waveform-based method of phase-space reconstruction for signal quality estimation on a single lead ECG was proposed by projecting the amplitude of the ECG and its first order difference into grid cells. The waveform of a single lead ECG was divided into non-overlapping episodes (Ts = 10, 20, 30 s), and the number of grids in both the width and the height of each map are in the range [20, 100] (NX = NY = 20, 30, 40, … 90, 100). The blank pane ratio (BPR) and the entropy were calculated from the distribution of ECG sampling points which were projected into the grid cells. Signal Quality Indices (SQI) bSQI and eSQI were calculated according to the BPR and the entropy, respectively. The MIT-BIH Noise Stress Test Database was used to test the performance of bSQI and eSQI on ECG signal quality estimation. The signal-to-noise ratio (SNR) during the noisy segments of the ECG records in the database is 24, 18, 12, 6, 0 and - 6 dB, respectively. For the SQI quantitative analysis, the records were divided into three groups: good quality group (24, 18 dB), moderate group (12, 6 dB) and bad quality group (0, - 6 dB). The classification among good quality group, moderate quality group and bad quality group were made by linear support-vector machine with the combination of the BPR, the entropy, the bSQI and the eSQI. The classification accuracy was 82.4% and the Cohen's Kappa coefficient was 0.74 on a scale of NX = 40 and Ts = 20 s. In conclusion, the novel grid mapping offers an intuitive and simple approach to achieving signal quality estimation on a single lead ECG.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Bode Plots Construction
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...