Related Experiment Video
Updated: Feb 18, 2026

Using Capillary Electrophoresis to Quantify Organic Acids from Plant Tissue: A Test Case Examining Coffea arabica Seeds
Published on: November 12, 2016
Detection of coffee adulteration with soybean and corn by capillary electrophoresis-tandem mass spectrometry
Daniela Daniel1, Fernando Silva Lopes2, Vagner Bezerra Dos Santos3
1Agilent Technologies, Alameda Araguaia, 1142, CEP 06455-000 Barueri, SP, Brazil; Departamento de Química Fundamental - Instituto de Química - Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, CEP 05508-000 São Paulo, SP, Brazil.
Abstract:
The detection of coffee adulteration with soybean and corn by capillary electrophoresis-tandem mass spectrometry was accomplished by evaluating the monosaccharides profile obtained after acid hydrolysis of the samples. The acid hydrolysis, using H2SO4 as a catalyst, increases the ionic strength of the sample impairing the electrophoretic separation. Therefore, Ba(OH)2 was used to both neutralize the medium and reduce the content of sulfate by precipitation of BaSO4. The best separation of nine determined monosaccharides (fucose, galactose, arabinose, glucose, rhamnose, xylose, mannose, fructose and ribose) plus inositol as internal standard was obtained in 500 mmol·L-1 triethylamine, pH 12.3. The monosaccharides are separated as anionic species at this pH. The proposed method is simple, fast (<12.0 min), present linear calibration curves (r2 = 0.995), and relative standard deviation for replicate injections lower than 5%. The LOQ for all monosaccharides was lower than 0.01 mmol·L-1, which is in accordance with the tolerable limits for coffee. Principal component analysis (PCA) was used to evaluate interrelationships between the monosaccharide profile and the coffee adulteration with different proportions of soybean and corn. Fucose, galactose, arabinose, glucose, sucrose, rhamnose, xylose, mannose, fructose, and ribose were quantified in packed roast-and-ground commercial coffee samples, and differences between adulterated and unadulterated coffees could be detected.
More Related Videos
08:01Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
Published on: December 15, 2015
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....