A separable quadratic surrogate total variation minimization algorithm for accelerating accurate CT reconstruction from few-views and limited-angle data
Related Experiment Video
Updated: Feb 18, 2026

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
Published on: November 23, 2019
Xiaowen Hou1, Yueyang Teng1, Yan Kang1
1Sino-Dutch Biomedical and Information School, Northeastern University, Shenyang, China.
Purpose:
Total variation minimization (TVM) is a popular and useful method for accurate CT reconstruction from few-views and limited-angle data. However, the optimization procedure of previous TVM-based algorithms is very time-consuming. The purpose of this paper was to accelerate the high image quality CT reconstruction from few-views and limited-angle data.
Method:
A new optimization algorithm based on the optimization transfer principle is proposed. The proposed algorithm uses TVM as the regularization term of the cost function that ensures the quality of the CT image reconstructed from few-views and limited-angle data. Additionally, half of the square of the difference between the original projection and the forward projection is used as the fidelity term. We then proved that the regularization term, i.e., 2-norm TV, is a convex function. Based on the convexity of the regularization and fidelity terms, a separable quadratic surrogate (SQS) function was proposed to substitute the regularization and fidelity terms. The solution of the cost function can be obtained by minimizing the SQS function and building the next SQS function at the minimum point.
Results:
Both numerical simulations and simulations using real experimental data showed that the proposed algorithm reconstruct high-quality CT image from few-views and limited-angle data. The differences between the image reconstructed by the proposed algorithm and the images reconstructed by the previous algorithms are very small. However, the proposed algorithm required less than 1/10 time of the computational time of the previous algorithms. The image quality is not assessed in a rigorous way.
Conclusion:
The proposed algorithm can greatly accelerate the accurate CT reconstruction from few-views and limited-angle data relative to previous algorithms.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
08:55Cryo-Electron Tomography Remote Data Collection and Subtomogram Averaging
Published on: July 12, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Quadratic Models
Imaging Studies III: Computed Tomography