Spectro-Temporal Electrocardiogram Analysis for Noise-Robust Heart Rate and Heart Rate Variability Measurement
Diana P Tobon1, Srinivasan Jayaraman1, Tiago H Falk1
1INRS-EMTUniversité du Québec.
Abstract:
The last few years has seen a proliferation of wearable electrocardiogram (ECG) devices in the market with applications in fitness tracking, patient monitoring, athletic performance assessment, stress and fatigue detection, and biometrics, to name a few. The majority of these applications rely on the computation of the heart rate (HR) and the so-called heart rate variability (HRV) index via time-, frequency-, or non-linear-domain approaches. Wearable/portable devices, however, are highly susceptible to artifacts, particularly those resultant from movement. These artifacts can hamper HR/HRV measurement, thus pose a serious threat to cardiac monitoring applications. While current solutions rely on ECG enhancement as a pre-processing step prior to HR/HRV calculation, existing artifact removal algorithms still perform poorly under extremely noisy scenarios. To overcome this limitation, we take an alternate approach and propose the use of a spectro-temporal ECG signal representation that we show separates cardiac components from artifacts. More specifically, by quantifying the rate-of-change of ECG spectral components over time, we show that heart rate estimates can be reliably obtained even in extremely noisy signals, thus bypassing the need for ECG enhancement. With such HR measurements in hands, we then propose a new noise-robust HRV index termed MD-HRV (modulation-domain HRV) computed as the standard deviation of the obtained HR values. Experiments with synthetic ECG signals corrupted at various different signal-to-noise levels, as well as recorded noisy signals show the proposed measure outperforming several HRV benchmark parameters computed post wavelet-based enhancement. These findings suggest that the proposed HR measures and derived MD-HRV metric are well-suited for ambulant cardiac monitoring applications, particularly those involving intense movement (e.g., elite athletic training).
More Related Videos
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Electrophysiology of Normal Cardiac Rhythm