Oxidation of azo and anthraquinonic dyes by peroxymonosulphate activated by UV light

Michele Pagano1, Ruggiero Ciannarella1, Vito Locaputo1

  • 1a Consiglio Nazionale delle Ricerche, Istituto di Ricerca Sulle Acque (CNR-IRSA) , Via Francesco De Blasio, Bari , Italy.

Related Concept Videos

Aryldiazonium Salts to Azo Dyes: Diazo Coupling01:11

Aryldiazonium Salts to Azo Dyes: Diazo Coupling

The reaction of weakly electrophilic aryldiazonium (also called arenediazonium) salts with highly activated aromatic compounds leads to the formation of products with an —N=N— link, called an azo linkage. This reaction, presented in Figure 1, is known as diazo coupling and occurs without the loss of the nitrogen atoms of the aryldiazonium salt. Highly activated aromatic compounds such as phenols or arylamines favor the diazo coupling reaction. The coupling generally occurs at the para...
3.7K
Oxidation Numbers03:14

Oxidation Numbers

In redox reactions, the transfer of electrons occurs between reacting species. Electron transfer is described by a hypothetical number called the oxidation number (or oxidation state). It represents the effective charge of an atom or element, which is assigned using a set of rules.
43.3K
Pyruvate Oxidation01:15

Pyruvate Oxidation

After glycolysis, the charged pyruvate molecules enter the mitochondria via active transport and undergo three enzymatic reactions. These reactions ensure that pyruvate can enter the next metabolic pathway so that energy stored in the pyruvate molecules can be harnessed by the cells.
First, the enzyme pyruvate dehydrogenase removes the carboxyl group from pyruvate and releases it as carbon dioxide. The stripped molecule is then oxidized and releases electrons, which are then picked up by NAD+...
169.6K
Oxidation-Reduction Reactions03:11

Oxidation-Reduction Reactions

Oxidation–Reduction Reactions
75.9K
UV–Vis Spectrum01:30

UV–Vis Spectrum

When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.     
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
2.2K
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
3.8K