Neuromuscular electrical stimulation reduces sludge in the popliteal vein
Christopher R Lattimer1, Mustapha Azzam2, Jason A Papaconstandinou3
1Josef Pflug Vascular Laboratory, Ealing Hospital, Middlesex, United Kingdom; Department of Surgery and Cancer, Imperial College, London, United Kingdom; West London Vascular and Interventional Centre, Northwick Park Hospital, Middlesex, United Kingdom.
Background:
The common peroneal nerve stimulator (CPNS) is a UK-approved device for reducing venous thromboembolism (VTE) risk. It resembles a wrist watch and is placed over the common peroneal nerve, discharging electricity at a rate of 1 impulse/s. It has been presumed that as blood flow slows, erythrocytes aggregate into ultrasound-detectable echogenic particles, described as venous sludge. The aim of the study was to determine whether the CPNS reduces venous sludge by using an ultrasound-derived gray-scale (0-255) venous sludge index (VSI).
Methods:
Twenty-five healthy volunteers had their right popliteal vein video recorded using B-mode ultrasound at 22 frames/s in longitudinal and transverse views, standing and lying. This was performed first with the CPNS off and then with the CPNS on. The CPNS impulse intensity used was set from 1 to 7 for each individual, and the level was sufficient to cause an outward jerking movement of the foot. A single frame of the possible 154 frames, lasting 7 seconds, was selected using a random number generator for the image analysis. The "brightness" of the erythrocyte aggregates (pixels) within a circular sampling area was quantified using the VSI. The brighter the sample, the greater the sludge.
Results:
Values are expressed as median (interquartile range). On standing with the device off, there was a significantly higher VSI (P < .0005) compared with lying (longitudinal view, 27.7 [18.8-41.4] vs 11.7 [5.5-17.5]; transverse view, 20.7 [13.6-32.2] vs 11.4 [6.3-15.9]). Activation of the CPNS significantly reduced all the VSI values (P < .0005) shown (longitudinal view, 2 [1.1-3.2] and 1.5 [0.5-3.1]; transverse view, 1.1 [0.6-2.7] and 0.8 [0.5-2.1]).
Conclusions:
The CPNS device significantly reduces venous sludge within the popliteal vein irrespective of whether the subject is standing or lying down or of the longitudinal or transverse position of the ultrasound transducer. The principal mode of action of the device in the claim that it may reduce venous thromboembolism risk may be through a reduction of venous sludge. However, the relationship between erythrocyte aggregation, venous stasis, and venous thromboembolism risk requires more investigation.
Related Concept Videos
Veins
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of...
The Neuromuscular Junction
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Veins of Thorax
The azygos vein, positioned just right of the midline and anterior to the vertebral column, begins at the junction of the right ascending lumbar and subcostal veins, terminating in the superior vena cava. This vein drains blood from the right side of the thoracic wall, thoracic viscera, and posterior abdominal wall.
The...
Veins of Lower Limbs
Formed by the union of the medial and lateral plantar veins, the posterior tibial vein, rising through the calf muscle, assimilates the fibular vein. The anterior tibial vein, a superior extension of the foot's dorsalis pedis vein, merges with the posterior tibial vein at the...
Neuromuscular Junction And Blockade