Related Experiment Video
Updated: Feb 16, 2026

Stereotactic Radiosurgery for Gynecologic Cancer
Published on: April 17, 2012
Dosimetry of a novel rotating gamma system for stereotactic radiosurgery
Kuang-Ming Yang1,2, Steen J Madsen3, Wei-Li Chen1
1Department of Biomedical Images and Radiological Sciences, National Yang-Ming University, 155, Sec.2, Li-Nong Street, Taipei, 112, Taiwan.
Abstract:
This is the first report of the basic dosimetric properties of a new rotating gamma system: the RGS Vertex360™. Dosimetric properties were compared to those measured with traditional rotating gamma systems and with the Leksell Gamma Knife. The RGS Vertex360 is similar to the original rotating gamma system developed by OUR New Medical Technology Development Co., Ltd. (Shenzen, China), however, there are a few notable differences including the angular arrangement of the sources. Basic dosimetric properties of the RGS Vertex360 were measured including: absorbed dose rate, output factors, mechanical and radiation center accuracy and dose profiles. A significant discrepancy was observed for the 4 mm output measured from the RGS Vertex360 compared to those obtained from previous rotating gamma units: the 4 mm output from the RGS Vertex360 (0.807) was 32-38% higher than those measured from previous units. This is somewhat surprising considering the excellent agreement in 4 mm outputs from the RGS Vertex360, the corresponding outputs specified by the manufacturer of the original OUR unit and those measured for the Leksell Gamma Knife. The mechanical accuracy was similar to previous rotating gamma systems while the 50-90% penumbra was narrower. Dose profiles compared favorably with the Leksell Gamma Knife: in many instances the measured penumbra was narrower for the RGS Vertex360. Notwithstanding the 4 mm output factor, the dosimetric properties of the RGS Vertex360 compared favorably with those of previous rotating gamma systems. The 4 mm output discrepancy was attributed to suboptimal alignment of the primary and secondary collimators in previous studies. The dosimetric properties of the RGS Vertex360 and the Leksell Gamma Knife were similar and, taken together, the results suggest that the new rotating gamma system is well suited for stereotactic radiosurgery procedures.
Related Concept Videos
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...
Rotation of Asymmetric Top
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...
Rotation with Constant Angular Acceleration - I
Using our intuition, we can begin to see how rotational quantities such as angular displacement, angular velocity, angular acceleration, and time are related to one another. For example, if a flywheel...
Rotation with Constant Angular Acceleration - II
The first...
Apparent Weight and the Earth's Rotation
For an object on the Earth's equator, the net centripetal force that accounts for its rotation is the Earth's pull towards its center, or the weight minus the normal force that prevents it from piercing into the Earth's surface....
Rotational Motion about a Fixed Axis

