Head to head comparison of two commercial phantoms used for SRS QA
Vikren Sarkar1, Long Huang1, Yu-Huei Jessica Huang1
1Department of Radiation Oncology, University of Utah, Salt Lake City, UT 84112, USA.
Abstract:
Multiple commercial phantoms are now available for performing end-to-end QA testing for stereotactic procedures. This project aims at directly comparing one of the newest phantoms on the market against a more established one by performing similar tests to determine whether results are similar and they can be used interchangeably. Both phantoms were used to evaluate the coincidence of radiation and laser isocenters of a linear accelerator. End-to-end dosimetric tests were also performed using both an ion chamber and film. As part of the testing, both phantoms were also evaluated in terms of their efficiency of setup as well as the time required to switch inserts for different tests. Results showed that the laser/radiation isocenter coincidence as determined from each phantom was highly correlated. Ion chamber results were within 0.5% of the expected values. Gamma (2%, 2mm) pass rates of corresponding films were within 2% between phantoms. These results show that both phantoms are capable of producing equivalent results for the QA tests evaluated here.
Related Concept Videos
Muscles that Move the Head
The bilateral sternocleidomastoid, or SCM, and the suprahyoid and infrahyoid muscles are significant head flexors. The SCM muscles originate at the sternum and clavicle and attach to the mastoid process of the temporal bone. The SCM contracts bilaterally to bend the head forward, whereas...
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons