Coupling of Noncrossing Wave Modes in a Two-Dimensional Plasma Crystal

J K Meyer1, I Laut1, S K Zhdanov1

  • 1Institut für Materialphysik im Weltraum, Deutsches Zentrum für Luft- und Raumfahrt (DLR), 82234 Weßling, Germany.

Physical Review Letters
|January 6, 2018
PubMed
Summary

We observed coupled dust-lattice waves in a 2D complex plasma crystal without mode crossing. This coupling, seen in transverse vertical and longitudinal in-plane modes, was confirmed by simulations and theory.

Related Concept Videos

Modes of Standing Waves - I01:03

Modes of Standing Waves - I

A close look at earthquakes provides evidence for the conditions appropriate for resonance, standing waves, and constructive and destructive interference. A building may vibrate for several seconds with a driving frequency matching the building's natural frequency of vibration; this produces a resonance that results in one building collapsing while the neighboring buildings do not. Often, buildings of a certain height are devastated, while other taller buildings remain intact. This...
4.1K
Modes of Standing Waves: II01:04

Modes of Standing Waves: II

The starting point for expressing the modes of standing waves is understanding the boundary conditions that the waves must follow. The boundary conditions are derived from the physical understanding of how the standing waves are sustained, that is, how the vibrating particles of the medium behave at the boundaries imposed on them.
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....
1.8K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.5K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
1.9K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
2.1K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
788