Feasibility and Validity of Printing 3D Heart Models from Rotational Angiography
Manoj Parimi1, John Buelter1, Vignan Thanugundla2
1Saint Louis University School of Medicine, 1402 South Grand Blvd, St. Louis, MO, 63104, USA.
Abstract:
Rotational angiography (RA) has proven to be an excellent method for evaluating congenital disease (CHD) in the cardiac cath lab, permitting acquisition of 3D datasets with superior spatial resolution. This technique has not been routinely implemented for 3D printing in CHD. We describe our case series of models printed from RA and validate our technique. All patients with models printed from RA were selected. RA acquisitions from a Toshiba Infinix-I system were postprocessed and printed with a Stratasys Eden 260. Two independent observers measured 5-10 points of interest on both the RA and the 3D model. Bland Altman plot was used to compare the measurements on rotational angiography to the printed model. Models were printed from RA in 5 patients (age 2 months-1 year). Diagnoses included (a) coronary artery aneurysm, (b) Glenn shunt, (c) coarctation of the aorta, (d) tetralogy of Fallot with MAPCAs, and (e) pulmonary artery stenosis. There was no significant measurement difference between RA and the printed model (r = 0.990, p < 0.01, Bland Altman p = 0.987). There was also no significant inter-observer variability. The MAPCAs model was referenced by the surgeon intraoperatively and was accurate. Rotational angiography can generate highly accurate 3D models in congenital heart disease, including in small vascular structures. These models can be extremely useful in patient evaluation and management.
Related Concept Videos
Reliability and Validity
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...
Anatomy of the Heart
Rotation of Asymmetric Top
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...