Related Experiment Video
Updated: Feb 15, 2026

Stromal Vascular Fraction-enriched Fat Grafting for the Treatment of Symptomatic End-neuromata
Published on: November 23, 2017
Three-dimensional Volumetric Analysis of 3 Fat-Processing Techniques for Facial Fat Grafting: A Randomized Clinical
Rongwei Wu1, Xiaonan Yang1, Xiaolei Jin1
1Department No. 16, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Importance:
Autologous fat grafting has revolutionized the field of facial soft-tissue augmentation, despite a lack of standardization. Objective data are needed to arrive at consensus regarding the best technique for optimal volume retention.
Objective:
To compare 3 fat-processing techniques with 3-dimensional (3-D) technology to explore the optimal fat-processing technique for improving the volume retention of grafted fat.
Design, Setting, And Participants:
From September 2015 to December 2016, patients with facial asymmetry were treated by initial facial fat grafting at the Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College. Sixty-three patients (21 per group) were randomized to 1 of 3 fat-processing techniques: sedimentation, centrifugation, and cotton pad filtration. Patients underwent 3-D scanning preoperatively and at 1, 3, 6, and 12 months postoperatively. Patients who did not complete preoperative or postoperative follow-up and 3-D imaging were excluded from the analysis.
Intervention:
Autologous fat grafting to correct facial asymmetry.
Main Outcomes And Measures:
The percentage volume maintenance of each fat-processing technique was measured with 3-D software and analyzed with variance analysis.
Results:
Of the 63 randomized patients, 30 (7 men, 23 women; mean [SD] age at surgery, 22.2 [8.0] years) completed follow-up. The mean (SD) percentage volume maintenance of the 3 groups at 1, 3, 6, and 12 months postoperatively was, respectively, 49% (4%), 45% (3%), 43% (3%), and 41% (3%) for the cotton pad filtration group; 41% (3%), 38% (4%), 36% (4%), and 34% (3%) for the centrifugation group; and 37% (4%), 34% (4%), 31% (3%), and 31% (3%) for sedimentation group. The variance analysis showed that the cotton pad filtration group demonstrated a statistically significant higher percentage volume maintenance in comparison with the centrifugation and sedimentation groups.
Conclusions And Relevance:
The use of 3-D technology provides an objective and accurate way to evaluate different fat-processing techniques. Autologous fat processed by cotton pad filtration had a significant higher volume retention than did that processed by centrifugation and sedimentation technique.
Trial Registration:
chictr.org.cn Identifier: ChiCTR-IOR-14005599.
Level Of Evidence:
1.
Related Concept Videos
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Statistical Software for Data Analysis and Clinical Trials
Fats as Energy Storage Molecules
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...