Related Experiment Video
Updated: Feb 15, 2026

Rapid Isolation of Human Breast Milk-Derived Extracellular Vesicles
Published on: November 14, 2025
Variability and reliability of POP concentrations in multiple breast milk samples collected from the same mothers
Risa Kakimoto1, Masayoshi Ichiba2, Akiko Matsumoto2
1Department of Environmental Science, Graduate School of Agriculture, Saga University, Honjo 1, Saga, 840-8502, Japan.
Abstract:
Risk assessment of infant using a realistic persistent organic pollutant (POP) exposure through breast milk is essential to devise future regulation of POPs. However, recent investigations have demonstrated that POP levels in breast milk collected from the same mother showed a wide range of variation daily and monthly. To estimate the appropriate sample size of breast milk from the same mother to obtain reliable POP concentrations, breast milk samples were collected from five mothers living in Japan from 2006 to 2012. Milk samples from each mother were collected 3 to 6 times a day through 3 to 7 days consecutively. Food samples as the duplicated method were collected from two mothers during the period of breast milk sample collection. Those were employed for POP (PCBs, DDTs, chlordanes, and HCB) analysis. PCB concentrations detected in breast milk samples showed a wide range of variation which was maximum 63 and 60% of relative standard deviation (RSD) in lipid and wet weight basis, respectively. The time course trend of those variations among the mothers did not show any typical pattern. A larger amount of PCB intake through food seemed to affect 10 h after those concentrations in breast milk in lipid weight basis. Intraclass correlation coefficient (ICC) analyses indicated that the appropriate sample size for good reproducibility of POP concentrations in breast milk required at least two samples for lipid and wet weight basis.
More Related Videos
07:38Milk Collection in the Rat Using Capillary Tubes and Estimation of Milk Fat Content by Creamatocrit
Published on: December 16, 2015
10:53Concentration of Virus Particles from Environmental Water and Wastewater Samples Using Skimmed Milk Flocculation and Ultrafiltration
Published on: March 17, 2023
Related Concept Videos
Reliability and Validity
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Concentration Cells
Consider the following voltaic cell:
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Graphs of Equations in Two Variables