Related Experiment Video
Updated: Feb 15, 2026

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
The Association Between Ventilator Dyssynchrony, Delivered Tidal Volume, and Sedation Using a Novel Automated
Peter D Sottile1, David Albers2, Carrie Higgins1
1Division of Pulmonary Sciences and Critical Care Medicine, Department of Medicine, University of Colorado School of Medicine, Aurora, CO.
Objective:
Ventilator dyssynchrony is potentially harmful to patients with or at risk for the acute respiratory distress syndrome. Automated detection of ventilator dyssynchrony from ventilator waveforms has been difficult. It is unclear if certain types of ventilator dyssynchrony deliver large tidal volumes and whether levels of sedation alter the frequency of ventilator dyssynchrony.
Design:
A prospective observational study.
Setting:
A university medical ICU.
Patients:
Patients with or at risk for acute respiratory distress syndrome.
Interventions:
Continuous pressure-time, flow-time, and volume-time data were directly obtained from the ventilator. The level of sedation and the use of neuromuscular blockade was extracted from the medical record. Machine learning algorithms that incorporate clinical insight were developed and trained to detect four previously described and clinically relevant forms of ventilator dyssynchrony. The association between normalized tidal volume and ventilator dyssynchrony and the association between sedation and the frequency of ventilator dyssynchrony were determined.
Measurements And Main Results:
A total of 4.26 million breaths were recorded from 62 ventilated patients. Our algorithm detected three types of ventilator dyssynchrony with an area under the receiver operator curve of greater than 0.89. Ventilator dyssynchrony occurred in 34.4% (95% CI, 34.41-34.49%) of breaths. When compared with synchronous breaths, double-triggered and flow-limited breaths were more likely to deliver tidal volumes greater than 10 mL/kg (40% and 11% compared with 0.2%; p < 0.001 for both comparisons). Deep sedation reduced but did not eliminate the frequency of all ventilator dyssynchrony breaths (p < 0.05). Ventilator dyssynchrony was eliminated with neuromuscular blockade (p < 0.001).
Conclusion:
We developed a computerized algorithm that accurately detects three types of ventilator dyssynchrony. Double-triggered and flow-limited breaths are associated with the frequent delivery of tidal volumes of greater than 10 mL/kg. Although ventilator dyssynchrony is reduced by deep sedation, potentially deleterious tidal volumes may still be delivered. However, neuromuscular blockade effectively eliminates ventilator dyssynchrony.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation I: Indication and Settings